The repeater must be set in S-mode or T1 mode and it will only repeat SND-NR or SND-IR messages according the OMS. Try to repeat your test in T1 mode and verify that you send and SND-IR or SND-NR. If you still get it to work only in ‘accept all’ mode for the master it may be that you have installed the slave address incorrectly. Check Most significant byte vs Least Significant Byte order for the A-field and M field.
Last Update: October 10, 2017
October 10, 2017 1684 Wireless M-Bus Q&A