Yes, you can remove the jumpers on P13 and connect a RS232 level converter directly to the RXT/TXD pins of the module (START bit low and STOP bit high). Board details in the kit User Manual
Last Update: November 9, 2017
November 9, 2017 1587 RC232 Q&A
Related Knowledge Base Posts -
- [RC232] “I have problem to wake up RS1240 from sleep mode, in fact I can’t wake it up at all. According to documentation, config pin should be asserted when going to sleep mode, and then positive edge should wake ip module This is code I use: Config Portd.3 = Output : Modem_config Alias Portd.3 Modem_config = 1 ‘ ———— PUT MODEM IN SLEEP MODE Modem_config = 0 ‘ Assert Config pin Waitms 5 ‘ MAX Time from CONFIG pin is set low until prompt (“”>””) Print “”Z””; ‘ Goto SLEEP mode . . . Sub Send_packet Modem_config = 1 ‘ Wake up form SLEEP mode Waitms 60 ‘ Wait 60 ms to get out from sleep mode Print “”X””; ‘ Goto idle mode Led_tx = 1 Printbin Paket_start Printbin Data_packet Led_tx = 0 Modem_config = 0 ‘ Assert Config PIN Waitms 5 ‘ MAX Time from CONFIG pin is set low until prompt (“”>””) Print “”Z””; ‘ SLEEP mode End Sub But, module stuck in sleep mode, and dont send enything. When I comment all lines regarding sleep mode, module work fine. Where I’m wrong? I should deliver device this week, and this is only problem I have to resolve. “
- [RC232] Question regarding RC232 in Star mode (many to one). If more than node will transmit at same to central point – will RC232 protocol queue data somehow, or there will be collision or data will be lost?
- [RC232] In a point to multi point scenario, (host with clients) can the host see the received signal levels of the clients when they transmit data?