Inside the module is confidential information and part of our IP. You will get or the thecnical specification of the module from our data sheet.
Last Update: August 8, 2017
January 25, 2017 1653 RC232 Q&A
Related Knowledge Base Posts -
- [RC232] “I have problem to wake up RS1240 from sleep mode, in fact I can’t wake it up at all. According to documentation, config pin should be asserted when going to sleep mode, and then positive edge should wake ip module This is code I use: Config Portd.3 = Output : Modem_config Alias Portd.3 Modem_config = 1 ‘ ———— PUT MODEM IN SLEEP MODE Modem_config = 0 ‘ Assert Config pin Waitms 5 ‘ MAX Time from CONFIG pin is set low until prompt (“”>””) Print “”Z””; ‘ Goto SLEEP mode . . . Sub Send_packet Modem_config = 1 ‘ Wake up form SLEEP mode Waitms 60 ‘ Wait 60 ms to get out from sleep mode Print “”X””; ‘ Goto idle mode Led_tx = 1 Printbin Paket_start Printbin Data_packet Led_tx = 0 Modem_config = 0 ‘ Assert Config PIN Waitms 5 ‘ MAX Time from CONFIG pin is set low until prompt (“”>””) Print “”Z””; ‘ SLEEP mode End Sub But, module stuck in sleep mode, and dont send enything. When I comment all lines regarding sleep mode, module work fine. Where I’m wrong? I should deliver device this week, and this is only problem I have to resolve. “
- [RC232] In a point to multi point scenario, (host with clients) can the host see the received signal levels of the clients when they transmit data?
- [RC232] We are trying to configure our modems RC2500HP 201545H to use them at a data rate of 250kbit/s, following the datasheet rev 1.22. However the communication fails at this RF rate. Back to 100 kbit/s the communication is works again.