ZNM Q&A
Enter your keywords to find answers:
Technical questions from customers, answered by Radiocrafts' support engineers, about ZigBee (ZNM) modules.
No questions match your filter.
01Does the Zigbee module such as RC2400-ZNM have the same footprint as the OMS \RC1180-MBUS3? If yes, is our OMS board could be used also for the Zigbee module?
The footprint / size is the same, but please see the detailed pinout in the datasheets for the two modules. For example, the ZNM module may also use SPI which is not available on the MBUS3 module.
02Where can I find more info on the FCC approval?
Guidelines for using the FCC approved modules in the correct way is given in our datasheet.
By searching the FCC web pages ( https://www.fcc.gov/oet/ea/fccid) for Grantee ID : Y2N, you can find all public documentation for our FCC approved modules.
03Where can I find info on the application profiles?
We recommend to download the latest public specification of the profile in interest from : www.zigbee.org -> ZigBee for developers.
04What is ZigBee?
ZigBee is the wireless language that everyday devices use to connect to one another. In fact, ZigBee could be at work in your home right now.
05What is the difference between RC2400HP and RC2400HP-ZNM?
The RC2400HP is a hardware platform module. It is made for customers that want to develop their own embedded FW on it, either a ZigBee solution based on Z-stack from TI or a proprietary protocol.
The RC2400HP-ZNM include a precompiled / preloaded ZigBee PRO network stack. Through an API over UART/SPI an external application processor can setup, manage and send/receive data.
06What HW/FW will you send me? If I receive HW 3.2 that’s a different product than 2.1 – according to the PCN there is a difference in layout, PCB material and thicker chipset.
We will send the latest version of the module (HW and FW). New versions will always be backward compatible. If changed a PCN will be issued.
07Were can I find more info on the FCC approval?
Guidelines for using the FCC approved modules in the correct way is given in our datasheet.
By searching the FCC web pages ( https://www.fcc.gov/oet/ea/fccid) for Grantee ID : Y2N, you can find all public documentation for our FCC approved modules.
08We are using RC2400HP-ZNM for street smart lightning. We want to connect the lamps to the corresponding gateways.
Looking at your case, it seems like you want to configure 3 networks. This is possible by using 3 different PAN IDs. Only nodes with PAN ID that match the gateway PAN ID will join the network.
09we are looking for some wireless nodes that implement 802.15.4 in the 2,4GHz band
"We do offer a series of 802.15.4/ZigBee modules.
Our HW-offerings include two different physical sizes and also different antenna options.
RC240x
This is an ultra compact variant measuring only 12.7x25.4mm (0.5'' x 1') for limited PCB area usage. This solution is also pin compatible with our wireless M-Bus, KNX-RF and RC232 solution
RC241xAT
The AT variant include an internal chip antenna on the module. This makes the antenna design easy and also very compact.
RC241xCT
The CT variant includes an U.FL compliant connector. This enables the use of an external antenna giving flexibility and also enables the use of high preformance whip antennas.
All our 802.15.4 modules is available as extended range versions (-HP). These module include both an internal power amplifier in transmit and a low noise amplifier in receive to maximize range. This gives an impressive system value of 119 dB, which indicate a line of sight range of above 2.5 km with a good antenna.
We also offer a range of firmware solution to suit all customers. We offer these ZNM-firmware based in ZigBee® PRO. It is preloaded with a ZigBee® PRO compliant stack and offers an easy to use API via UART or SPI to an external processor. The external application processor can be of any type or brand, and the development can be done with the tool and platform most convenient to the developer.
Some customer wants to write their own SW solution based on a supplied ZigBee stack, 802.15.4 MAC stack or proprietary solution. We also offer HW platform for this this. Our module is compliant with ZigBee PRO certified Z-stack from Texas Instruments. Based on this free-of-charge stack, the customers can write their own application inside the RC24xx HW platforms. With a total flash size of 256kB we offer the largest space for customer application in the market.
"
10There is no UART communication from the module. What can be wrong?
Please verify the following:
Check that module has voltage on VCC pin.
Make sure the config pin for selecting UART is pulled low. (Left floating the internal pullup will setup module in SPI mode)
11Regarding the software Smart RF packet sniffer : It is possible to see the data that we send from one board to other board ?
Yes, the sniffer should show all communication between the units
12Regarding decoupling, the datasheet does not mention the decoupling capacitors required to supply the module. Are they integrated into the module?
There are decoupling internally, and there ere no requirement from module of external decoupling.
But your final design must of course also consider the possible noise and ripple in the supply voltage coming from other circuitry in your product.
13Is there available example code for the host controller for talking to the ZNP module
Yes, downloading the Z-stack Mesh variant at http://www.ti.com/tool/z-stack-archive will also give an example code for using the ZNP interface. Example code is written for MSP430.
14Is the ZigBee protocol included in the module?
The -ZNM variant or our product includes a Z-stack from Texas Instruments which is ZigBee compliant. The application layer (Home Automation/Light Link)) must be added in in externally or the user can makes his proprietary application.
15In the RC1180 datasheet it is stated that the tolerance is +/- 2% in transmission and reception. In transmission the radio module has good communication quality. What is the tolerance of the RC1180 in reception mode?
On the UART transmitter of RC1180 we have actually better performance than specified. The tolerance is typ 0.2 %. Unfortunately we do not have an accurate number for the receiver tolerance at the moment, but it will at least accept +/- 2% tolerance.
16I’ve been going through your datasheet of the RC2300-ZNM module. I guess that your are using the TI CC2430 under the hood. Two MCU’s for an on/off switch sounds expensive. Isn’t it possible to bind IO of RC2300-ZNM module to a specific configured application endpoint on the same module?
"Yes, you could use only one controller (the 8051) but then you have to acquire compiler for that, a programmer and
read all the header files and compile the FW yourselves. The ZNM- module can not operate stand-alone.
So its really a tradeoff between unit cost and development cost+ time."
17I want to talk to the ZNP interface from Linux. Are there any help available?
Yes. Please look at http://www.ti.com/tool/TIDC-ZNP-HOST-SW3#Technical Documents
18I am interested to use your IEEE 802.15.4, ZigBee-and 6LoWPAN modules.
"Thank you for the interest in our ZigBee / 6LoWPAN radio modules.
We have a large family of module called RC24xx
RC2400 (Basic)
RC2400HP (20 dBm output power)
RC2411AT Integrated chip antenna
RC2411CT U.FL connector
RC2411HP-AT (20 dBm + chip antenna)
RC2411HP-CT (20 dBm + u.fl connector)
All FCC/IC, CE certified.
For ZigBee you get then with embedded ZigBee stack and a easy to use serial interface This version is called -ZNM (ZigBee Network module) For ZNM the application is in external host MCU.
If you want to develop the application inside the module you should use Z-Stack from Texas Instruments. A market leading ZigBee PRO stack.
It is free of charge available from TI.
Please let us know if you have more questions.
"
19Does your product support ZigBee Light Link?
Yes, we do support ZLL. Software for the ZLL golden units are found here: http://www.ti.com/tool/z-stack-archive
20Does your product support ZigBee 3.0
We do support ZigBee 3.0, but currently only at build it yourself solution. Z-stack for ZigBee 3.0 is available here and the porting guide is available from our website.
21Do you have a user manual for RC2411?
We have merged the two user manual for RC2400 and RC241x as they are 90% the same.
22Do Radiocrafts support 868/915 MHz ZigBee?
No. 868 MHz ZigBee is used in niche markets.
23Could you confirm that the RC2400 HP ZNM are using Z stack revision 2.3.0 . It is possible to have Z stack revision 3.0?
Latest revision is based on rev 2.5.1a. (2017-07-17) Please find PCN enclosed.
24Can we use your ZNM module for a proprietary solution?
Yes, our ZNM module can be used with proprietary stack. The physical radio is limited to 2.4 GHz IEEE 802.15.4. As long as you stay below a max TX duty cycle of 27ms/100ms the FCC ID will still be valid. The protocol can be developed from scratch or based in PHY/MAC stack such as TI-MAC
25Can the ZNM modules be used worldwide?
Yes, the 2.4 GHz band is world wide. The output power limitation difference from region to region. E.g. the maximum output power in EU is limited to 12 dBm due to limits in power spectral density given in EN 300 328.
26Can the ZNM module support transparent data?
No, the data has to be packaged in a SendData packet / frame format.
27We use the Zigbee Network module RC241x/RC241xHP and we would like to know if this devices are ESD sensible. Can you give us the ESD sensibility?
"The ESD level depend on the PINs
Pin 32 + pin37 + UFL connector
600 V HBM, 500V CDM
All other pins have ESD level
2kV HBM and 500V CDM
"
28We have started a design with TI’s ZNP solution (CC2530). We where also interested in adding the PA/LNA chip (CC2591) for extended range. Based on what I found on the web, this is the same architecture you use in your RC2400HP-ZNM module. I like this module because it’s very compact. My first question would be if we can use the ZNP version of the stack with this? I would guess so, but a confirmation would be appreciated. I’m interested to do a comparison between building our own PCB with TI parts or simply integrate your module.
"Yes, the module can be used with ZNP. We already have this functionality embedded in our ZNM- modules.
There are a couple of important differences between usinga chip-set and our module.
1. Preformance, gettingthe best preformance is not necessary easy
2. FCC/IC approval. We are in the middle of FCC/IC certifying our module
We also have a different physical form of the module with embedded chip antenna or U.FL connector.
We need to look into using an inverted F antenna. The FCC certification will be valid for a set with antenna and currently inverted F PCB antenna is not part of that.
It is easier if you could use the chip antenna RC2411HP-AT
3. Testing 100 % of our modules are tested in a test robot(ATS).
4.Stability. We spent the most time in design/verification to get the CC2591 stable for all temperatures and voltages.
5. Time to market. Estimate 1 year from design starts until product is finalized with chip design.
"
29We are still looking at the RC2400HP-ZNM module. If we want to save on the certification cost for FCC and ETSI, what approach would you recommend? Do you offer this module with a ceramic chip antenna? If so, could you provide details about range, radiation pattern and layout recommendations of such module?
"Yes, we have an variant of the module with ceramic chip antenna.
Attached datasheet contains radiation pattern, recommended layout etc.
If you put a PCB antenna on your board there have to be additional test and FCC-recertification. (That I understand you do not want to do)
Yes, you must do EMC (unintentional radiation ) on final product.
We have seen a challenge in addition for ETSI EN 300 328.
If you use High power version, you can transmit more than allowed if you send maximum power.
The power level can of course be tuned down, however that correct setting to use varies between end products.
This is due to the peak radiation from the product change depending on module placement and on ground plane size/shape.
So I would recommend 1 hour in an ambionic chamber to optimize output power. (~2-3% cost of full ETSI/FCC/IC)
"
30We are little bit confused about sending data. Do we need to send data shown in example with space or can we send data continuously. For example, we are gonna send data as FE 01 41 00 00 40, do we need to send space between each byte or can we send data as FE0141000040?
| There is no space between each byte. They are just written this way for human readability. |
31I’m developing a Zigbee application with your product, RC2400HP-ZNM(SN : RC2400HP 201026). The moudule is controlled via SPI as attached drawings. When I execute H/W reset to ZNM, I can see “”SRDY”” to “”low”” and the result of POLL command is “”064180010200020300″”. I think it’s the value of “”SYS_RESET_IND””, is it right?
CORRECT, this is RESET_IND
32For executing “”SYS_RESET_REQ”” command, I’ve processed as follows; set “”MRDY and SS”” to “”low”” & check the status of “”SRDY”” to “”low”” -> in host processor, sent “”SYS_RESET_REQ”” command -> waited the result of “”SDRY”” to “”high””, but not appeared
"System reset request is an asynchronous request (AREQ)
0x 01 41 00 00
After this is received the SRDY should go high.
If is doesn't I would expect that the ZNM module have not received the expected number of bytes.
"