KNX Q&A
Enter your keywords to find answers:
Technical questions from customers, answered by Radiocrafts' support engineers, about KNX RF modules.
No questions match your filter.
01Where can I find KNX User Manual?
The KNX User Manual is available for download after registering at the web site.
02What KNX do you support?
"The KNX-RF radio module is a complete embedded radio solution compliant with the KNX standard.
The KNX-RF module is compliant with the new Multi version of the protocol, which has several new features to improve and secure radio communication.
The radiomodule has the complete KNX-RF stack embedded and has a packet handler for easy-to-use interface.
"
03What is the difference between KNX1, KNX2 and KNX3?
Only KNX2 is available and recommended for new designs. KNX1 is obsolete, and KNX3 is a future product.
04What is the difference between KNX and KNX RF?
The KNX protocol can run over different types of media; twisted pair, power line communication and wireless. The wireless is referred to as KNX RF. The wireless protocol has been expanded from the original KNX RF into the KNX RF Multi, where “multi” refers to multiple frequencies, making the wireless communication frequency agile.
05What is KNX?
KNX is an international standard used for home and building automation, typically controlling light, heat and ventilation. It is standardized in ISO/IEC 14543.
06What is KNX RF Multi?
KNX RF Multi is the latest wireless protocol for KNX, replacing KNX RF and KNX Ready. It supports frequency agility (5 frequencies), fast and slow modes, listen before talk, fast acknowledge from up to 64 devices with retry if not successful, and repeaters (re-transmitters). All these features make the KNX RF Multi very reliable and robust wireless protocol for building control applications. Radiocrafts offer the complete KNX RF Multi protocol in the RC1180-KNX2 module.
07What frequencies are supported by KNX RF?
The standard frequency band for KNX RF is 868 MHz (RC1180-KNX2). For non-European countries there is a 433 MHz variant that can be used (RC1140-KNX2).
08Not easy to monitor the RSSI value, only click the RSSI button on GUI of KNX-CCT can read it, Could you tell how to monitor the RSSI continuously?
Continuous RSSI monitoring is not supported, but the KNX module has an option to add one byte on the UART informing about the signal on the received packet.
09No user manual for KNX-CCT, just refer from RC232-CCT manual. But I still cannot know the configure description such as RF_Power, RSSI mode, etc. Could you tell which documents can find the definition?
The document you need is the KNX User Manual available from our web after register and signing in.
10KNX-RF configuration done in ETS?
You need to build an applicaton on top, which will work with the ETS during link and installing a system
11Is it possible to get the ETS5 product files regarding the RC1180-KNX2?
Regarding the ETS system: since we only provide the KNX compatible radio module and not the end-product, we do not supply any ETS related model. It is the responsibility of the end-product owner to create and supply the market with the correct end-product model. However, since our radio module is according to the KNX standard, there should be no problem to use it in any products model.
12Is it possible to get the ETS5 prod fileregarding the RC1180-KNX2?
Since we only provide the KNX compatible radio module and not the end-product, we do not supply any ETS related model. It is the responsibility of the end-product owner to create and supply the market with the correct end-product model. However, since our radio module is according to the KNX standard, there should be no problem to use it in any products model.
13Is it possible to configure KNX2 to control a roller shutter via RF just like the remote RF control?
Best advice is to order the development kit and use the Packet sniffer / Packet generation PC tools so transmit command to the motor. In sniffer mode you can receive and analyze the packet format from the official remote control and use this packet format to generate your own control packets.
14Is it full control?
The protocol embedded by Radiocrafts has all the radio communication including a packet handler inside. We have embedded support for the KNX-RF Easy and the new KNX-RF Multi.
15In the datasheet of CC1180-KNX2, the max TX power is +10dBm, but have checked by spectrum analyzer conductively (Test_cfg.jpg), the max power is only about 0dBm (TX_Power capture.JPG). Could you tell why there is 10dB difference? Is there anything wrong with my test setup or setup of demo board? Please refer the cfg file of KNX-CCT as 1180-KNX2.rcc
5. Your enclosed plot informs that you measure on modulated specter. This will not give correct measuring results unless you change RBW settings on your SA to measure the total signal. Alternative you can use Test Mode 1 to enable carrier TX (no modulation). See KNX User Manual for details.
16If i need more 50 device RF (for example), what do I i do to not have problem with a signals?? Can i link a specifics devices of any installation on 1 module RF but not in 2nd RF knx (two rf-knx device installed in same place)? If i need more 50 device RF (for example) how i do to not have problem with a signals??
The KNX module follow the KNX specification and includes powerful mechanism to avoid collision and ensure that communication goes to the right node. LBT (Listen Before Talk) is handled automatically by the module in the way that the module goes into RX mode and check if the channel is free before transmitting data. In addition you install the serial number into the address register to filter out incoming packets not intended for this module. This ensures that the module only accept packets form units with correct serial number.
For details please see KNX User Manual available at:
https://radiocrafts.com/products/knx/#Documentation
17I wonder if the KNX-RF radiomodule can recive Z-wave 868Mhz?
"Unfortunally not. The RC1180-KNX2 module sends and received according to the KNX-RF standard
while Z-Wave in a propriatary system som Zensys/Sigma design.
"
18Do you have any practical configuration example to use the module like a live KNX device?
The KNX Demo software can run on a PC and contains pre-defined KNX messages that can be used to emulate a light switch.
19Could you tell any way to monitor the BER (or CRC error)? Because I’d like to perform the test of error-free RF distance
The module takes care of CRC check and only correct packets is sendt out on the UART from the recveiver. You can use the KNX-DEMO packet sniffer to count number of received packets and calculate Packet Error Rate based on known nuber of packet transmitted.
20Could you provide ETS product file?
Radiocrafts does not provide ETS files, this is something the end equipment manufacturer should provide.
21Can you provide the ISO/IEC 14543 standard documents?
No, the standard documents can be purchased as a personal/company copy from ISO or your local standardization body (such as DIN, BSI, AFNOR etc).
22As I can see the RC232-CCT is not suitable for KNX2-demo kit because the .RMD file is missing. As well as the RC232-SA.
RC232-CCT and RC232-SA is not supporting the KNX module. You need to install the RCTools-KNX to get supported variants for your KNX module.
231- What frequencies you are using?
KNX-RF is using the 868-870MHz area. There are also opening to use 433MHz, but all the 433MHz frequencies are not specified yet
24Recently we have purchased the RC1180DK KNX2 demonstration kit from you. However, we have been unable to get it working. The boards are not transmitting/receiving messages. I have tried using the DEMO application to send packets using the KNX packet generator, while the other board is used as KNX packet sniffer. But nothing shows in the sniffer. Thereafter, I checked the configuration memory and it contains mostly 0x00 and 0xFF. See also attached file (configuration_knx2.txt). Then I loaded the factory settings using the load factory settings in the KNX-CCT tool, but the program gives me an exception error at the end. I am also not able to load settings with the program then. See attached file configuration_knx2_default.txt for the default settings that are loaded. The default settings does not seem to match the ones mentioned in the KNX user manual. Do you have an idea what the problem is and how we can get the transmission working?
The configuration memory in the module has been corrupted. Then the Tool will not recognize the module anymore and further the module will not work properly. You can verify this by using the MBUS-CCT PC application to read the whole config memory using the 0 command. You may also use the M command to restore the part name location is corrupted. The KNX-CCT will recognize the module again, and you can do a factory reset in the file:Load factory setting menu. For details plese see CCT User Manual
25is it possible to get a KNW RF modul to control a bose lifestyle musicsystem via KNX
Our company provides KNX-RF modules (868 MHz band) to be used in KNX products. We do not provide final product solutions. For certified KNX products please check out ww.knx.org.
26If i need more 50 device RF (for example), what do I i do to not have problem with a signals?? Can i link a specifics devices of any installation on 1 module RF but not in 2nd RF knx (two rf-knx device installed in same place)? If i need more 50 device RF (for example) how i do to not have problem with a signals??
"The KNX module follow the KNX specification and includes powerful mechanism to avoid collision and ensure that communication goes to the right node. LBT (Listen Before Talk) is handled automatically by the module in the way that the module goes into RX mode and check if the channel is free before transmitting data. In addition you install the serial number into the address register to filter out incoming packets not intended for this module. This ensures that the module only accept packets form units with correct serial number. For details please see KNX User Manual available at:
https://www.radiocrafts.com/index.php?sideID=538&ledd2=536
"
27I am interested about a device to comunicate KNX devices with web server Ethernet via HTTP Protocol, receive KNX values and send to Ethernet via HTTP_Request POST or PUT, and receive value via HTTPRequest_Get. What kind of device have I to buy to do it, no matter if I have to programmer the device?
"The KNX RF module we have do have a specific UART interface with a specific format of the data, see KNX User Manual on our website.
In order to connect the RF module to Ethernet you must have an external MCU with Ethernet support, and you must program inside this MCU the code which takes
the IP-stack, which is normally for free, and you must embed the UART communication and UART API towards the module on top of this stack. So there are some programming efforts to
achieve this. I assume you have already chosen a MCU with Ethernet and UART and has already figured out how to hook it up to the Ethernet. Then the UART traffic is quite straight forward.
"