MBUS3 and MBUS4 cannot be configured over the air. MPC1 supports configuration over the air, provided it has been enabled in the module. In this case, when the module CONFIG pin is activated, the module will transmit the current configuration setup. A response to this message will reconfigure the module with the new settings provided.
Last Update: August 8, 2017
December 13, 2016 1771 Wireless M-Bus Q&A