500mW is the max output power allowed in EU to comply with EN300220 at 868 MHz. For this reason we do not have a module for higher output power than 500mw. |
Last Update: September 22, 2017
September 22, 2017 1532 RC232 Q&A
Related Knowledge Base Posts -
- [RC232] “The data rates for the high speed module RC1180HP is more suitable for our needs, but we need to have the possibility to increase the range with a high gain antenna or any kind of amplifier, could that be possible? “
- [RC232] “I have problem to wake up RS1240 from sleep mode, in fact I can’t wake it up at all. According to documentation, config pin should be asserted when going to sleep mode, and then positive edge should wake ip module This is code I use: Config Portd.3 = Output : Modem_config Alias Portd.3 Modem_config = 1 ‘ ———— PUT MODEM IN SLEEP MODE Modem_config = 0 ‘ Assert Config pin Waitms 5 ‘ MAX Time from CONFIG pin is set low until prompt (“”>””) Print “”Z””; ‘ Goto SLEEP mode . . . Sub Send_packet Modem_config = 1 ‘ Wake up form SLEEP mode Waitms 60 ‘ Wait 60 ms to get out from sleep mode Print “”X””; ‘ Goto idle mode Led_tx = 1 Printbin Paket_start Printbin Data_packet Led_tx = 0 Modem_config = 0 ‘ Assert Config PIN Waitms 5 ‘ MAX Time from CONFIG pin is set low until prompt (“”>””) Print “”Z””; ‘ SLEEP mode End Sub But, module stuck in sleep mode, and dont send enything. When I comment all lines regarding sleep mode, module work fine. Where I’m wrong? I should deliver device this week, and this is only problem I have to resolve. “
- [RC232] What is the data transmission rate of the 1180HP at 5 km ?