Skip to content Skip to content
  • PCN Sign Up
  • Newsletter Sign Up
  • Log In
  • Register
  • My Profile
  • LinkedIn
  • YouTube
  • Facebook
  • GitHub
Radiocrafts
Radiocrafts
  • Home
  • Products
    • MIOTY Network
      • MIOTY Parts and Tools
    • RIIM™ Network
      • RIIM™ Parts and Tools
      • Cloud To Sensor Prototype Network By RIIM™
    • Wireless M-Bus
      • WIZE
      • W-MBUS Sensor Interfacing Modules (MSM)
      • RC1702HP For Custom Applications
    • RC232™
    • Tinymesh
    • Customizable
    • Wireless Mesh Modbus Extender
    • Development Kits
      • Buy A Development Kit/Samples
      • Development Kit Support
      • USB Sticks
      • Expansion Boards For Gateways
  • Services
    • Design Services
  • Applications
    • Emergency Lighting
    • EV Charger Communication
    • Smart Irrigation
      • Next-Gen Smart Irrigation Evaluation Kit
    • Smart Metering
      • Wireless M-Bus Smart Metering Modules
      • Mioty For Smart Metering
    • Smart Street Lighting
    • Solar
      • Next-Gen Solar Evaluation Kit
    • Sub-Metering
    • Wireless Sensor Networks
  • Technologies
    • RIIM
    • Wireless M-Bus
    • Wize Alliance and Wize Technology
    • Wireless Modbus
    • RC232
    • Tinymesh™
  • News
    • Events
  • Resources
    • Blog
    • Document Library
    • Declarations of Conformity
    • PCN & Errata
      • FW Product Change Notifications
      • HW Product Change Notifications
    • Quality & Certification
    • Supporting Software & Software Tools
      • Supporting Software Descriptions
    • Webinars & Video Snippets
  • Support
    • Customer Support Page
    • Distributor Support Page
    • Radiocrafts FAQ
    • Radiocrafts Technical Support Q&A
  • About
    • Radiocrafts & Management
    • Career
    • Success Stories and Reference Cases
  • Distributors
  • Contact
  • Home
  • Products
    • MIOTY Network
      • MIOTY Parts and Tools
    • RIIM™ Network
      • RIIM™ Parts and Tools
      • Cloud To Sensor Prototype Network By RIIM™
    • Wireless M-Bus
      • WIZE
      • W-MBUS Sensor Interfacing Modules (MSM)
      • RC1702HP For Custom Applications
    • RC232™
    • Tinymesh
    • Customizable
    • Wireless Mesh Modbus Extender
    • Development Kits
      • Buy A Development Kit/Samples
      • Development Kit Support
      • USB Sticks
      • Expansion Boards For Gateways
  • Services
    • Design Services
  • Applications
    • Emergency Lighting
    • EV Charger Communication
    • Smart Irrigation
      • Next-Gen Smart Irrigation Evaluation Kit
    • Smart Metering
      • Wireless M-Bus Smart Metering Modules
      • Mioty For Smart Metering
    • Smart Street Lighting
    • Solar
      • Next-Gen Solar Evaluation Kit
    • Sub-Metering
    • Wireless Sensor Networks
  • Technologies
    • RIIM
    • Wireless M-Bus
    • Wize Alliance and Wize Technology
    • Wireless Modbus
    • RC232
    • Tinymesh™
  • News
    • Events
  • Resources
    • Blog
    • Document Library
    • Declarations of Conformity
    • PCN & Errata
      • FW Product Change Notifications
      • HW Product Change Notifications
    • Quality & Certification
    • Supporting Software & Software Tools
      • Supporting Software Descriptions
    • Webinars & Video Snippets
  • Support
    • Customer Support Page
    • Distributor Support Page
    • Radiocrafts FAQ
    • Radiocrafts Technical Support Q&A
  • About
    • Radiocrafts & Management
    • Career
    • Success Stories and Reference Cases
  • Distributors
  • Contact

[W-MBUS] Which Wireless M-Bus modes are supported?

MBUS3 support S1, S2, T1, T2, C1 modes. MBUS4 supports N1 and N2. The mode is set by configuration register 0x03 (MBUS_MODE). Also note that the module can be configured for receiving T and C mode in parallel, that is, the module will detect the mode and decode the message accordingly.

    Last Update: August 8, 2017  

    December 13, 2016   3440    Wireless M-Bus Q&A  

    Related Knowledge Base Posts -

    • [W-MBUS] I have another question, there is a command to use to read the key of one of the installed slaves (set with command 0x4B)?
    • [W-MBUS] “We do the test you proposed (DTR signal to a fixed voltage) but needs more details on how to do it. Could we set the DTR to 1 using the configuration program or must vie done in hardware? “
    • [W-MBUS] “In your mbus manual wrote (pag 4): “”In OMS (MBUS3) the master sends a command with its own address as Link Layer Address, and the slaves address as Application Layer Address.”” You mean that only long Appl header (12 byte) containing the slave address is granted ? If I got it the MUC and slaves have same link address (i.e MUC address) .. is it correct? Does your mailbox feature use this format ? “

     

    Products

     
    RIIM

    Wireless Mesh Modbus Extender

    Wireless M-Bus

    RC232

    Tinymesh

    mioty

    Customizables

    Development Kits

     

     

     

    Applications

     
    Smart Metering

    Sub-Metering

    Solar

    Smart Irrigation

    Emergency Lighting

    Wireless Sensor Networks

    Smart Street Lighting

    EV Charger Communication

     

     

     

    Resources

     
    Blog

    Document Library

    Declarations of Conformity

    FW Product Change Notification

    HW Product Change Notification

    Quality & Certification

    Software & Software Tools

    Webinars & Video Snippets

     

     

     

    Support

     
    Customer Support Page

    FAQ

    Technical Support Q&A

    Contact Form

    Global Distribution Partners

    Design & Customization Services

    Technical Dive into Technologies

     

     

     

    About Us

     
    Radiocrafts & Management

    News

    Events

    Career

    Success Stories & References Cases

     

    Newsletter Signup!

    © Copyright 2003-2025 Radiocrafts AS. Gullhaugveien 7, NO-0484, OSLO, Norway. Tel: +47 400 05 195.
    • Home
    • Products
      • MIOTY Network
        • MIOTY Parts and Tools
      • RIIM™ Network
        • RIIM™ Parts and Tools
        • Cloud To Sensor Prototype Network By RIIM™
      • Wireless M-Bus
        • WIZE
        • W-MBUS Sensor Interfacing Modules (MSM)
        • RC1702HP For Custom Applications
      • RC232™
      • Tinymesh
      • Customizable
      • Wireless Mesh Modbus Extender
      • Development Kits
        • Buy A Development Kit/Samples
        • Development Kit Support
        • USB Sticks
        • Expansion Boards For Gateways
    • Services
      • Design Services
    • Applications
      • Emergency Lighting
      • EV Charger Communication
      • Smart Irrigation
        • Next-Gen Smart Irrigation Evaluation Kit
      • Smart Metering
        • Wireless M-Bus Smart Metering Modules
        • Mioty For Smart Metering
      • Smart Street Lighting
      • Solar
        • Next-Gen Solar Evaluation Kit
      • Sub-Metering
      • Wireless Sensor Networks
    • Technologies
      • RIIM
      • Wireless M-Bus
      • Wize Alliance and Wize Technology
      • Wireless Modbus
      • RC232
      • Tinymesh™
    • News
      • Events
    • Resources
      • Blog
      • Document Library
      • Declarations of Conformity
      • PCN & Errata
        • FW Product Change Notifications
        • HW Product Change Notifications
      • Quality & Certification
      • Supporting Software & Software Tools
        • Supporting Software Descriptions
      • Webinars & Video Snippets
    • Support
      • Customer Support Page
      • Distributor Support Page
      • Radiocrafts FAQ
      • Radiocrafts Technical Support Q&A
    • About
      • Radiocrafts & Management
      • Career
      • Success Stories and Reference Cases
    • Distributors
    • Contact
    • Search Knowledgebase