[Tiny Mesh] Can the END point transmit data at any moment after wake up by external trigger (i.e GPIO), can END point initialize communication?

Yes – this is the default behaviour of an End Device.

When waking up from internal IMA timer, external GPIO, or serial data input, the device will first dispatch a packet as dictated by the trigger condition, then return to sleep.