[TINYMESH] Our question is when the RSSI level is updated in case of End Device operation. It is quite unconvienent to satisfy only with the first RSSI during ED’s powerup. Basically when the ED will move around or the RF environment will change how we will know it without restarting the ED’s node.

I’m afraid this is how it works. As the end device does not continuously receive data or beacons from its destination node, and hence is unable to update the received signal strength value. For an end device the reported Origin RSSI is the signal strength detected when the End Device first made connection to it’s destination node.

    Last Update: September 14, 2017  

    September 14, 2017   1582    Tinymesh Q&A